Ofen IVA MKG 2s 70/95/110

Verfahrenstechnik / Verfahrenstechnik

Hersteller: IVA

Modell: MKG 2s 70/95/110

Maschinentyp: Ofen

Eintrags-Nr.: 166929885

Anzahl: 1

Datum: 25.04.2025

Standort: Dresden, Germany

Preis:


Positionsnummer des Verkäufers: 7297705

Quenching of the Batch

The batch is quenched by immersion in a quenching medium (oil).

---------------------------------------------------------------

Dimensions and Weights

Overall Dimensions (including control system):

- Width: approx. 3400 mm
- Height: approx. 5600 mm
- of which recessed in the pit: 650 mm
- Length: approx. 5500 mm
- Minimum required hall height: 7000 mm
- Working height above floor level: 1200 mm
---------------------------------------------------------------

Base Grate Dimensions:

- Width: 705 mm
- Height: 50 mm
- Length: 1100 mm
---------------------------------------------------------------

Usable Batch Space (including base grate):

- Width: 700 mm
- Height: 950 mm
- Length: 1100 mm
- Grate loading height: 900 mm
- Gross batch weight (incl. base grate): 1000 kg
---------------------------------------------------------------

Oil Bath:

- Oil capacity: approx. 6000 liters
---------------------------------------------------------------

Weight:

- Empty furnace weight: approx. 15,000 kg
- Operating weight (incl. oil and batch): approx. 23,000 kg

Electrical and Gas Requirements:

- Voltage:
- 400 V, 50 Hz
- 230 V, 50 Hz
- 24 V DC
- Power Consumption:
- Approx. 85 kW
- Pre-pressure (Customer-supplied) for Natural Gas:
- 70-200 mbar
- Consumption per Ignition Burner (Natural Gas):
- Max. 700 l/h
- Connection Specifications for Safety Burners (Flame Curtains and Ignition Monitoring):
- Natural Gas: 8.0 Nm³/h
- Electric Heating/Cooling: 1000 °C / Heating cartridges / Inconel radiant tube 601
---------------------------------------------------------------

Burner and Gas Details:

- Manufacturer:
- [Brand Name]
- Number of Radiant Tubes: 6
- Maximum Heating Power per Tube: 30 kW
- Total Heating Power: 180 kW
- Natural Gas Consumption: Max. 18 m³/h
---------------------------------------------------------------

Protective or Reactive Gases:

- Pressure Equalization - Pre-chamber Nitrogen:
- Each cycle (4-6 bar storage, customer-supplied): Safety Gas (Purge Gas) Nitrogen (3 bar, customer-supplied)
- Carbonization Gas (Nitrogen/Methanol):
- Nitrogen (3 bar, customer-supplied): approx. 6 Nm³/h
- Methanol (1.2 bar, customer-supplied): approx. 6 NI/h
- Carbonization Gas (3 bar, customer-supplied): approx. 12 Nm³/h

Find more here - /

Contact us at -
Diese Maschine auf Facebook
Diese Maschine als verkauft

Anfrageformular

Sind Sie Händler?

Bitte senden:

Gesuchsanfrage?

Kopie an Sie?

Eingabedaten speichern?

Quenching of the Batch

The batch is quenched by immersion in a quenching medium (oil).

---------------------------------------------------------------

Dimensions and Weights

Overall Dimensions (including control system):

- Width: approx. 3400 mm
- Height: approx. 5600 mm
- of which recessed in the pit: 650 mm
- Length: approx. 5500 mm
- Minimum required hall height: 7000 mm
- Working height above floor level: 1200 mm
---------------------------------------------------------------

Base Grate Dimensions:

- Width: 705 mm
- Height: 50 mm
- Length: 1100 mm
---------------------------------------------------------------

Usable Batch Space (including base grate):

- Width: 700 mm
- Height: 950 mm
- Length: 1100 mm
- Grate loading height: 900 mm
- Gross batch weight (incl. base grate): 1000 kg
---------------------------------------------------------------

Oil Bath:

- Oil capacity: approx. 6000 liters
---------------------------------------------------------------

Weight:

- Empty furnace weight: approx. 15,000 kg
- Operating weight (incl. oil and batch): approx. 23,000 kg

Electrical and Gas Requirements:

- Voltage:
- 400 V, 50 Hz
- 230 V, 50 Hz
- 24 V DC
- Power Consumption:
- Approx. 85 kW
- Pre-pressure (Customer-supplied) for Natural Gas:
- 70-200 mbar
- Consumption per Ignition Burner (Natural Gas):
- Max. 700 l/h
- Connection Specifications for Safety Burners (Flame Curtains and Ignition Monitoring):
- Natural Gas: 8.0 Nm³/h
- Electric Heating/Cooling: 1000 °C / Heating cartridges / Inconel radiant tube 601
---------------------------------------------------------------

Burner and Gas Details:

- Manufacturer:
- [Brand Name]
- Number of Radiant Tubes: 6
- Maximum Heating Power per Tube: 30 kW
- Total Heating Power: 180 kW
- Natural Gas Consumption: Max. 18 m³/h
---------------------------------------------------------------

Protective or Reactive Gases:

- Pressure Equalization - Pre-chamber Nitrogen:
- Each cycle (4-6 bar storage, customer-supplied): Safety Gas (Purge Gas) Nitrogen (3 bar, customer-supplied)
- Carbonization Gas (Nitrogen/Methanol):
- Nitrogen (3 bar, customer-supplied): approx. 6 Nm³/h
- Methanol (1.2 bar, customer-supplied): approx. 6 NI/h
- Carbonization Gas (3 bar, customer-supplied): approx. 12 Nm³/h

Find more here - /

Contact us at -
Verkäufer Angebot Nr. resale 7297705
Diese Maschine auf Facebook
Diese Maschine als verkauft
Geprüfter
Händler

Verkäufer

UCY Industrial GmbH

UCY Industrial GmbH

Herr Nick Breinfalk
82049 Pullach
Deutschland

RESALE Anbieter seit 2024

  • Maschinenliste (1390)

Anfrageformular

Sind Sie Händler?

Bitte senden:

Gesuchsanfrage?

(zu obiger Maschine eine Gesuchsanfrage an alle Händler senden)

Kopie an Sie?

(Kopie Ihrer Anfrage an Ihre Emailadresse)

Eingabedaten speichern?

(Eingabedaten für weitere Anfragen speichern)

aktuelle IVA MKG 2s 70/95/110 + ähnliche IVA-Modelle