Back-pressure turbine
Manufacturer: Fa. KKK
First Start-up: 2002
Operating Hours of Turbine: 30.000h
Type: CFR5 G6a
Power Max: 2500 kW
Operational efficiency: 2200 kW
Revolution number: 23000 U /min
Live steam pressure: 65 bar
Live steam pressure temperature: 480 oC
Evaporation pressure: 1-17 bar
Investments in the year 2002 Entire steam transforming station from 63 bar to 2,5 bar renewed in 2002, El. Generator Fa. Leroy Somer, el. Power 2 MW
renewed
Entire measuring -, governing and control of the turbine renewed
Steam turbine renewed
Installed boiler efficiency:
Boiler I Hard coal
Steam generation: 20 t/h, 63 bar, 495 oC
Boiler II Hard coal
Steam generation: 13 t/h, 34 bar, 425 oC
Boiler III: Combination burner for oil and gas
Steam generation: 20 t/h, 17 bar, 285 oC
General overhaul of the entire plant from 2002 to 2004
Steam generator renewed
automatic cole-loader and ashremoval plant renewed
Water treatment plant renewed
entire instrumentation renewed
Flue gas purification plant Fa. Lurgie of 1991 - 2001 renewed

Errors excepted!
Diese Maschine auf Facebook
Diese Maschine als verkauft

Anfrageformular

Sind Sie Händler?

Bitte senden:

Gesuchsanfrage?

Kopie an Sie?

Eingabedaten speichern?

Back-pressure turbine
Manufacturer: Fa. KKK
First Start-up: 2002
Operating Hours of Turbine: 30.000h
Type: CFR5 G6a
Power Max: 2500 kW
Operational efficiency: 2200 kW
Revolution number: 23000 U /min
Live steam pressure: 65 bar
Live steam pressure temperature: 480 oC
Evaporation pressure: 1-17 bar
Investments in the year 2002 Entire steam transforming station from 63 bar to 2,5 bar renewed in 2002, El. Generator Fa. Leroy Somer, el. Power 2 MW
renewed
Entire measuring -, governing and control of the turbine renewed
Steam turbine renewed
Installed boiler efficiency:
Boiler I Hard coal
Steam generation: 20 t/h, 63 bar, 495 oC
Boiler II Hard coal
Steam generation: 13 t/h, 34 bar, 425 oC
Boiler III: Combination burner for oil and gas
Steam generation: 20 t/h, 17 bar, 285 oC
General overhaul of the entire plant from 2002 to 2004
Steam generator renewed
automatic cole-loader and ashremoval plant renewed
Water treatment plant renewed
entire instrumentation renewed
Flue gas purification plant Fa. Lurgie of 1991 - 2001 renewed

Errors excepted!

Verkäufer Angebot Nr. resale N0100
Diese Maschine auf Facebook
Diese Maschine als verkauft
Geprüfter
Händler

Verkäufer

Lenhart Ges. für Handel, Verwertung & Service mbH &Co.KG

Herr Markus Lenhart
55595 Wallhausen
Deutschland

RESALE Anbieter seit 2004

  • Maschinenliste (30)

Anfrageformular

Sind Sie Händler?

Bitte senden:

Gesuchsanfrage?

(zu obiger Maschine eine Gesuchsanfrage an alle Händler senden)

Kopie an Sie?

(Kopie Ihrer Anfrage an Ihre Emailadresse)

Eingabedaten speichern?

(Eingabedaten für weitere Anfragen speichern)

aktuelle KKK CFR5 G6a + ähnliche KKK-Modelle

2002 KKKCFR5 G6a

Preise: verkaufte KKK CFR5 G6a + ähnliche KKK-Modelle

1976 KKKCFR5 100000 EUR [Aug 2013]
1976 KKKCFR5 100000 EUR [Aug 2013]